H.—lsa
12
No. 3.—Return of Notices given to repair Boilers— continued.
■ umber. Type. Description of Repairs. 1 1 1 1 2 3 3 1 1 2 1 ' 1 1 1 1 1 1 2 1 1 3 1 1 4 14 1 1 1 1 1 I l Portable a New dog fitted to mudhole-door. New girder-stays fitted. New girders fitted to firebox-crown, retubed, front tube-plate patched, and a number of new screwed stays in firebox. New manhole-door. New mudhole-doors. New studs and nuts fitted to front mudhole-doors. New studs mudhole-doors. One mudhole compensated, and three new mudhole-doors fitted. One new longitudinal stay. One new screwed stay in firebox. One new screwed stay, and new stud in front mud-door. One new screwed stay, and one new mudhole-door. One new sling-stay fitted to crown of firebox. One new stay-tube. Patch fitted on crown of firebox. Patch fitted on shell, and six new screwed stays in firebox. Patch fitted on shell under blow-off cock. Patch fitted in firebox. Patch fitted in firebox, and mudhole-openings compensated. Patch fitted round skirting of firebox. Patch fitted to foundation-ring. Patch fitted to foundation-ring, and ring reriveted ; also three new longitudinal stays. Patch on firebox tube-plate renewed, and six new screwed stays. Patches renewed in firebox. Retubed. Retubed, new crown in firebox, and new girder-stays fitted. Retubed, new front tube-plate, two new longitudinal stays, and three new screwed stays. Retubed, new front tube-plate, and several new screwed stays. Retubed, new girders and bolts fitted to crown of firebox. Seven new screwed stays, and three new longitudinal stays fitted. Seventeen new screwed stays in firebox. Seventy new screwed stays in firebox, and mudhole-openings compensated. Several new screwed stays, patches fitted to corners of firebox and throat-plate. Six compensating-rings fitted to mudhole-openings. Six new screwed stays in firebox. Six new tubes. Six new tubes, and two new stay-tubes. Six new screwed stays, three mudhole-openings compensated, and patch renewed under fire-door. Sixteen new screwed stays in firebox. Tapered mudholes in front tube-plate retapped, and new plugs fitted. Thirty new screwed stays in firebox. Three new longitudinal stays. Three new longitudinal stays, two new screwed stays, and two mudhole-openings compensated. Thirty-six new screwed stays in firebox. Three new sling-stays fitted to crown of firebox. Three new tubes. Three patches fitted in firebox. Twelve new screwed stays in firebox. Twelve new tubes. Twelve new tubes, one new mud-door, and four new screwed stays. Twenty new screwed stays in firebox. Twenty-three new screwed stays in firebox. Twenty-three new screwed stays in firebox, and new stud in muddoor. 1 1 2 1 1 " 1 ..2 „ 1 1 1 1 1 1 1 1 1 1 2 4 1 2 4 5 1 1 „ Two new longitudinal stays, and two new tubes. Two new longitudinal stays. Two new screwed stays in firebox. Two new screwed stays in firebox, and one new longitudinal stay. Two new stays in firebox-crown, and mudhole-openings compensated. Two patches fitted on sides of firebox. 1 e/
Use your Papers Past website account to correct newspaper text.
By creating and using this account you agree to our terms of use.
Your session has expired.